pardeep
|
 |
« on: August 12, 2008, 01:43:22 » |
|
ONE LG MONITER 700E DOES NOT START. AT FIRST THE MONITER START AFTER SOME TIME ( 5 MINTUE, 10 MINTUE, HALF HOUR ,TIME INCREASE DAY BY DAY ) WITH SOUND OF RELAY AND WITH STABLE FRONT GREEN LED. NOW ONLY FRONT GREEN LED LIGHT BLINKING BUT MONITER DOES NOT START. ANY BODY KNOWS THE FAULT ?
|
|
|
|
|
Logged
|
BE HAPPY DONT WORRY
|
|
|
|
ROBIN HOOD
|
 |
« Reply #1 on: August 12, 2008, 02:04:45 » |
|
DEAR PARDEEP-- MAY BE MAIN FILTER CAPACITER OR ANY LOW POWER CAPACITOR IN POWER SUPPLY IS DEFECTIVE.. ANYWAY GOOD LUCK.
|
|
|
|
|
Logged
|
|
|
|
|
Maale
|
 |
« Reply #2 on: August 16, 2008, 16:49:08 » |
|
Check secondary caps
|
|
|
|
|
Logged
|
Don`t trouble troubles untill trouble troubles you
|
|
|
|
|
|
pardeep
|
 |
« Reply #4 on: August 17, 2008, 07:58:10 » |
|
THANKS RESPECTED FRIENDS--THE MONITER IS OK NOW. THE C954 1000/16 (470/16) IN POWER SUPPLY WAS DEFECTIVE. ANYWAY GREAT THANKS Maale , THANKS A LOT TO amnat.
|
|
|
|
|
Logged
|
BE HAPPY DONT WORRY
|
|
|
|
ashraf
|
 |
« Reply #5 on: August 19, 2008, 06:52:54 » |
|
(http://img184.imageshack.us/img184/5106/tr7eb16wm4.gif)
(http://img341.imageshack.us/img341/1390/tr7eb18tp4.gif)
|
|
|
|
|
Logged
|
|
|
|
|